Operating Principle : Photoacoustic
Range : 400 to 2000 ppm
Accuracy : ± (50 ppm + 5 % of reading)
Operating Temperature : -10 to 60 °C (14 to 140 °F)
Operating Principle : Laser Scattering
- PM2.5 :
- Range : 0 to 100 μg/m3
- Accuracy : 10%
- PM10 :
- Range : 100 to 1000 μg/m3
- Accuracy : 10%
- Operating Temperature : -10 to 60 °C (14 to 140 °F)
Operating Principle : Electrochemical
Range : 0 to 1.25 mg/m3
Accuracy : ±10%
Working Life : 6 Years
Operating Principle : Electrochemical
Range : 0 to 10 ppm
Accuracy : ±5%
Working Life : 2 Years
Operating Temperature : -20 to 60 °C (-4 tot 140 °F)
Relative Humidity : 10 to 90% (non-condensing)
Ingress Protection : IP30